-- Generated automatically by - EcosimPro - 4.8.0 USE PLANTA_SOLAR COMPONENT Campo_Solar2 TOPOLOGY PLANTA_SOLAR.Entrada_Flujo Entrada_Flujo1( datafile = "@PLANTA_SOLAR@/experiments") PLANTA_SOLAR.Configuracion_TUB Configuracion_TUB1( G = 0.5 * 11, Absortancia = 0.94, Reflectividad = 0.9 * 0.49, Transmisividad = 0.96, Reflectividadsecundaria = 0.77, factorensuciamiento1 = 0.8, factorensuciamiento2 = 0.8, pm = 8027, Cm = 500, diametrointeriortubo = 0.068, diametroexteriortubo = 0.071, Tint = 0.5) PLANTA_SOLAR.Salida_Flujo Salida_Flujo1( datafile = "@PLANTA_SOLAR@/experiments", Tini = 11.5) PLANTA_SOLAR.TUB_CAPTADOR( N = 64 -- Non default value. ) TUB_CAPTADOR1( incx = 1) PLANTA_SOLAR.Espejos Espejos1( datafile = "@PLANTA_SOLAR@/experiments/datafile/DATA110921.txt", -- Non default value. ano = 2011, mes = 9, dia = 21, longitud = -6, latitud = 37.41, hora_comienzo = 11.5) PLANTA_SOLAR.Sol Sol1( datafile = "@PLANTA_SOLAR@/experiments/datafile/DATA110921.txt" -- Non default value. ) CONNECT Sol1.S1 TO TUB_CAPTADOR1.S CONNECT Configuracion_TUB1.P TO TUB_CAPTADOR1.P CONNECT Entrada_Flujo1.F1 TO TUB_CAPTADOR1.F_In CONNECT TUB_CAPTADOR1.F_Out TO Salida_Flujo1.F_In CONNECT Espejos1.E1 TO TUB_CAPTADOR1.E END COMPONENT e-REdING. Biblioteca de la Escuela Superior de Ingenieros de Sevilla.


MODELO DE PARÁMETROS DISTRIBUIDOS EN ECOSIMPRO DE UN CAPTADOR SOLAR TIPO FRESNEL

: Torres Murillo, José Manuel
: Ingeniería Telecomunicación
Contenido del proyecto: